Customization: | Available |
---|---|
Portable: | Non Portable |
Form: | Flatbed |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
X-ray Generator | |
Ray Beam direction | Top-illuminated |
Tube current | 0.4~1.25mA(adjustable) |
Tube voltage | 100~160 kV(adjustable) |
Ray beam divergence angle | 90° |
The cooling / work cycle | Sealed oil cooling / 100% |
Image Processing System | |
X-ray sensor | L-shaped photodiode array detector (Multi-energy), 12bit depth |
Monitor | high resolution 17 inch LCD monitor |
Color image display | 24-bit true color display |
Console | full package sealed display, connecting cables can be adjusted according |
Edge Enhancement | the outline of objects will be more clear |
Super Image Enhancement | the details of the image are more clear |
High penetration display | improve image contrast in bright areas, so the easy penetrating area will be more clear |
Low penetration display | improve image contrast in dark areas, so the difficult penetrating area will be more clear |
Magnifier | local amplification function |
Brighten / darken | Increase/ decrease image brightness |
Image pull back / front pull | Show the top 20 images, and the current image can be any image processing |
Image Restoration | Restored to its original state |
Image Storage | Save any image in real time, and can store more than 100,000 images and be processed arbitrarily, continuous work to save. |
Film safety | ISO1600 film safety |
Technical standards | Technical parameters |
By size | 800(W)×650(H)mm |
Conveyor speed | 0.22m/s |
Load | 200 kg |
Resolution | 0.1 mm |
Penetration | ≥40 mm steel plate |
Through resolution | 0.202mm |
Spatial resolution | Horizontal diameter ≤1.0mm,Vertical diameter ≤1.0mm |
Conveyor height from the ground | 620mm |
Monitor | BenQ 17in LCD Monitor |
Storage | 500G hard drive to save any image in real time, can store more than 100,000 and can make any image processing, and continuous work to save. |
Noise | < 55dB(A) |
Operating system | windowsXP |
Single check dose | One-time inspection of the X-ray light source irradiation amount ≤ 1.5µGy |
Leaking radiation dose rate | Away from any device outer surface of 5cm, the ray irradiation leak rate should be < 0.05µGy/H |